M.
Ourak,
J.
Smits,
L.
Esteveny,
G.
Borghesan,
A.
Gijbels,
L.
Schoevaerdts,
Y.G.M.
Douven,
J.
Scholtes,
E.
Lankenau,
G.
H{"u}ttmann,
M.
Kozlovszky,
Gernot
Kronreif,
K.
Willekens,
P.
Stalmans,
Koorosh
Faridpooya,
M.
Cereda,
A.
Giani,
G.
Staurenghi,
D.
Reynaerts, and
E. B.
Vander Poorten,
Combined OCT distance and FBG force sensing cannulation needle for retinal vein cannulation: in vivo animal validation, International Journal of Computer Assisted Radiology and Surgery , vol. 14, no. 2, pp. 301--309, 2019.
Combined OCT distance and FBG force sensing cannulation needle for retinal vein cannulation: in vivo animal validation, International Journal of Computer Assisted Radiology and Surgery , vol. 14, no. 2, pp. 301--309, 2019.
DOI: | 10.1007/s11548-018-1829-0 |
File: | s11548-018-1829-0 |
Bibtex: | @Article{Ourak2019, author="Ourak, M. and Smits, J. and Esteveny, L. and Borghesan, G. and Gijbels, A. and Schoevaerdts, L. and Douven, Y. and Scholtes, J. and Lankenau, E. and Eixmann, T. and Schulz-Hildebrandt, H. and H{\"u}ttmann, G. and Kozlovszky, M. and Kronreif, G. and Willekens, K. and Stalmans, P. and Faridpooya, K. and Cereda, M. and Giani, A. and Staurenghi, G. and Reynaerts, D. and Vander Poorten, E. B.", title="Combined OCT distance and FBG force sensing cannulation needle for retinal vein cannulation: in vivo animal validation", journal="International Journal of Computer Assisted Radiology and Surgery", year="2019", month="Feb", day="01", volume="14", number="2", pages="301--309", abstract="Retinal vein cannulation is an experimental procedure during which a clot-dissolving drug is injected into an obstructed retinal vein. However, due to the fragility and minute size of retinal veins, such procedure is considered too risky to perform manually. With the aid of surgical robots, key limiting factors such as: unwanted eye rotations, hand tremor and instrument immobilization can be tackled. However, local instrument anatomy distance and force estimation remain unresolved issues. A reliable, real-time local interaction estimation between instrument tip and the retina could be a solution. This paper reports on the development of a combined force and distance sensing cannulation needle, and its experimental validation during in vivo animal trials.", issn="1861-6429", doi="10.1007/s11548-018-1829-0", url="https://doi.org/10.1007/s11548-018-1829-0", citation_key = {Ourak2019} } |
Gianni
Borghesan,
Mouloud
Ourak,
Eva
Lankenau,
Richard
Neffin,
Peter
Koch,
Hinnerk
Schulz-Hildebrandt,
Koen
Willekens,
Peter
Stalmans,
Dominiek
Reynaerts, and
Emmanuel Vander
Poorten,
Probabilistic Principal Component Analysis and Particle Filtering for real-time retina detection from a single-fiber OCT, in Proceedings of the 7th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery , 2017.
Probabilistic Principal Component Analysis and Particle Filtering for real-time retina detection from a single-fiber OCT, in Proceedings of the 7th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery , 2017.
Weblink: | https://www.researchgate.net/publication/320532046 |
Bibtex: | @conference{Borghesan2017, title = {Probabilistic Principal Component Analysis and Particle Filtering for real-time retina detection from a single-fiber OCT}, author = {Gianni Borghesan and Mouloud Ourak and Eva Lankenau and Richard Neffin and Peter Koch and Hinnerk Schulz-Hildebrandt and Koen Willekens and Peter Stalmans and Dominiek Reynaerts and Emmanuel Vander Poorten}, year = {2017}, date = {2017-06-02}, booktitle = {Proceedings of the 7th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery}, abstract = {Vitreo-retinal surgery concerns a set of particularly demanding micro-surgical interventions that take place at the back of the eye. Examples of such procedures are retinal vein cannulation (where the surgeon aims to insert a needle in a vein of the size of human hairs) and epiretinal membrane peeling (where a detached membrane must be removed from the retina). As severe retinal damage can be caused by undesired collisions, good instrument to retina distance perception would be very useful. We propose to use an OCT-fiber instrumented tool, and purposefully designed algorithms to interpret the measurements and extract a reliable real-time distance estimate. This abstract describes the progress that was made and includes a test conducted with a robotic platform on a synthetic eye mockup.}, keywords = {}, pubstate = {published}, tppubtype = {conference} } |
Ellen
Guder,
Eva
Lankenau,
F.
Fleischhauer,
Hinnerk
Schulz-Hildebrandt,
Gereon
Hüttmann,
H. W.
Pau, and
Tino
Just,
Microanatomy of the tympanic membrane in chronic myringitis obtained with optical coherence tomography, European Archives of Oto-Rhino-Laryngology , pp. 1-7, 2014.
Microanatomy of the tympanic membrane in chronic myringitis obtained with optical coherence tomography, European Archives of Oto-Rhino-Laryngology , pp. 1-7, 2014.
DOI: | 10.1007/s00405-014-3373-z |
File: | s00405-014-3373-z |
Bibtex: | @article{Guder2014, author = {Guder, Ellen and Lankenau, Eva and Fleischhauer, F. and Schulz-Hildebrandt, H. and Hüttmann, G. and Pau, H. W. and Just, Tino}, title = {Microanatomy of the tympanic membrane in chronic myringitis obtained with optical coherence tomography}, journal = {European Archives of Oto-Rhino-Laryngology}, pages = {1-7}, keywords = {Optical coherence tomography Tympanic membrane Chronic myringitis}, ISSN = {0937-4477}, DOI = {10.1007/s00405-014-3373-z}, url = {http://dx.doi.org/10.1007/s00405-014-3373-z}, year = {2014}, type = {Journal Article} } |
Philipp
Steven,
Carolin Le
Blanc,
Eva
Lankenau,
Marc
Krug,
Stefan
Oelckers,
Ludwig M
Heindl,
Uta
Gehlsen,
Gereon
Hüttmann, and
Claus
Cursiefen,
Optimising deep anterior lamellar keratoplasty (DALK) using intraoperative online optical coherence tomography (iOCT), British Journal of Ophthalmology , vol. 98, no. 7, pp. 900--904, 2014. BMJ Publishing Group Ltd.
Optimising deep anterior lamellar keratoplasty (DALK) using intraoperative online optical coherence tomography (iOCT), British Journal of Ophthalmology , vol. 98, no. 7, pp. 900--904, 2014. BMJ Publishing Group Ltd.
DOI: | 10.1136/bjophthalmol-2013-304585 |
File: | 900 |
Bibtex: | @article {Steven900, author = {Philipp Steven and Carolin Le Blanc and Eva Lankenau and Marc Krug and Stefan Oelckers and Ludwig M Heindl and Uta Gehlsen and Gereon Huettmann and Claus Cursiefen}, title = {Optimising deep anterior lamellar keratoplasty (DALK) using intraoperative online optical coherence tomography (iOCT)}, volume = {98}, number = {7}, pages = {900--904}, year = {2014}, doi = {10.1136/bjophthalmol-2013-304585}, publisher = {BMJ Publishing Group Ltd}, abstract = {Background/aims To describe the use of intraoperative online optical coherence tomography (iOCT) for improving deep anterior lamellar keratoplasty (DALK) surgery. Methods Retrospective case series of 6 eyes of 6 male patients with keratokonus, corneal dystrophy or herpetic stromal scars undergoing DALK were investigated using intraoperative optical coherence tomography and postsurgical image/video analysis. Main outcome measures were: visibility of surgical steps, especially, assessment of placement depth of injection needle, preparation of bare Descemet{\textquoteright}s membrane and drainage of interface fluid. Results iOCT enables real-time visualisation of all surgical steps of DALK procedure in all patients. Placement of air injection needle above Descemet{\textquoteright}s membrane was reliably monitored as was presence of bare Descemet{\textquoteright}s membrane and potential interface fluid. Conclusions iOCT assists with visualisation of injection needle placement and with assessment of bare Descemet{\textquoteright}s membrane as well as interface fluid during the DALK procedure. Overall iOCT may be a helpful device that supports surgeons in all steps of DALK procedure.}, issn = {0007-1161}, URL = {https://bjo.bmj.com/content/98/7/900}, eprint = {https://bjo.bmj.com/content/98/7/900.full.pdf}, journal = {British Journal of Ophthalmology} } |
Philipp
Steven,
Carolin Le
Blanc,
Marc
Krug,
Eva
Lankenau,
Ludwig M
Heindl,
Uta
Gehlsen,
Gereon
Hüttmann, and
Claus
Cursiefen,
Optimizing descemet membrane endothelial keratoplasty using intraoperative optical coherence tomography, JAMA Ophthalmology , vol. 131, no. 9, pp. 1135-42, 07 2013.
Optimizing descemet membrane endothelial keratoplasty using intraoperative optical coherence tomography, JAMA Ophthalmology , vol. 131, no. 9, pp. 1135-42, 07 2013.
DOI: | 10.1001/jamaophthalmol.2013.4672 |
Bibtex: | @article{10.1001/jamaophthalmol.2013.4672, author = {Steven, Philipp and Le Blanc, Carolin and Velten, Kai and Lankenau, Eva and Krug, Marc and Oelckers, Stefan and Heindl, Ludwig M. and Gehlsen, Uta and Hüttmann, Gereon and Cursiefen, Claus}, title = "{Optimizing Descemet Membrane Endothelial Keratoplasty Using Intraoperative Optical Coherence Tomography}", journal = {JAMA Ophthalmology}, volume = {131}, number = {9}, pages = {1135-1142}, year = {2013}, month = {09}, abstract = "{Descemet membrane endothelial keratoplasty (DMEK) is a challenging procedure for the surgeon, particularly because of deficient visibility of the delicate tissue due to the natural en face view through the operating microscope. A cross-sectional view would greatly enhance intraoperative overview and enable the surgeon to better control the procedure. To retrospectively analyze the use of intraoperative optical coherence tomography (iOCT) for improving the safety of DMEK.Intraoperative OCT during DMEK was performed in 26 eyes of 26 patients. We retrospectively analyzed imaging and video data. Department of Ophthalmology, University of Cologne.Seven men and 19 women aged 39 to 93 years with corneal endothelial dysfunction undergoing DMEK.Descemet membrane endothelial keratoplasty.Visibility of surgical steps, overall duration of DMEK, overall time for complete intraoperative air filling of the anterior chamber, and correlation between donor age and Descemet rolling behavior.Intraoperative OCT enables visualization of all steps of the DMEK procedure. Overall mean (SD) duration of the DMEK procedure was 25.7 (6.9) minutes when using iOCT. Overall mean (SD) complete intraoperative anterior chamber air-filling time was 236 (108) seconds in contrast to 60 to 90 minutes for standard air-filling time. Descemet membrane rolling behavior showed significant inverse correlation between donor age (range, 39-93 years) and the extent of rolling (R2 = 0.5 [P = .006]).Intraoperative OCT enhances the visibility of graft orientation and unfolding, thereby improving safety of the DMEK procedure. Overall, iOCT is a helpful device that may support surgeons in all steps of DMEK procedures.}", issn = {2168-6165}, doi = {10.1001/jamaophthalmol.2013.4672}, url = {https://doi.org/10.1001/jamaophthalmol.2013.4672}, eprint = {https://jamanetwork.com/journals/jamaophthalmology/articlepdf/1708786/eoi130143.pdf}, } |
B.
Olzowy,
N.
Starke,
T.
Schuldt,
Gereon
Hüttmann,
Eva
Lankenau, and
Tino
Just,
Optical coherence tomography and confocal endomicroscopy for rhinologic pathologies: a pilot study, in Head and Neck Optical Diagnostics , Christian Betz and Brian J. F. Wong M.D., Eds. SPIE, 062013. pp. 880505.
Optical coherence tomography and confocal endomicroscopy for rhinologic pathologies: a pilot study, in Head and Neck Optical Diagnostics , Christian Betz and Brian J. F. Wong M.D., Eds. SPIE, 062013. pp. 880505.
DOI: | 10.1117/12.2033174 |
File: | 12.2033174 |
Bibtex: | @inproceedings{10.1117/12.2033174, author = {B. Olzowy and N. Starke and T. Schuldt and G. H{\"u}ttmann and E. Lankenau and T. Just}, title = {{Optical coherence tomography and confocal endomicroscopy for rhinologic pathologies: a pilot study}}, volume = {8805}, booktitle = {Head and Neck Optical Diagnostics}, editor = {Christian Betz and Brian J. F. Wong M.D.}, organization = {International Society for Optics and Photonics}, publisher = {SPIE}, pages = {880505}, keywords = {optical coherence tomography, confocal microscopy, inverted papilloma , chronic rhinosinusitis, nasal polyps, mucociliary function, ciliated epithelium}, year = {2013}, doi = {10.1117/12.2033174}, URL = {https://doi.org/10.1117/12.2033174} } |
T.
Just,
H. W.
Pau, and
E.
Lankenau,
OCT in the field of laryngology: further perspectives, Nikiforos, Kollias and Bernard, Choi and Haishan, Zeng and Hyun Wook, Kang and Bodo, E. Knudsen and Brian, J. Wong and Justus, F. R. Ilgner and Kenton, W. Gregory and Guillermo, J. Tearney and Laura, Marcu and Henry, Hirschberg and Steen, J. Madsen and Andreas, Mandelis and Anita, Mahadevan-Jansen and Jansen, E. Duco, Eds. SPIE, 2011. pp. 78831W.
OCT in the field of laryngology: further perspectives, Nikiforos, Kollias and Bernard, Choi and Haishan, Zeng and Hyun Wook, Kang and Bodo, E. Knudsen and Brian, J. Wong and Justus, F. R. Ilgner and Kenton, W. Gregory and Guillermo, J. Tearney and Laura, Marcu and Henry, Hirschberg and Steen, J. Madsen and Andreas, Mandelis and Anita, Mahadevan-Jansen and Jansen, E. Duco, Eds. SPIE, 2011. pp. 78831W.
T.
Just,
E.
Lankenau, and
H. W.
Pau,
An optical coherence tomography study for imaging the round window niche and the promontorium tympani, Nikiforos, Kollias and Bernard, Choi and Haishan, Zeng and Reza, S. Malek and Brian, J. Wong and Justus, F. R. Ilgner and Kenton, W. Gregory and Guillermo, J. Tearney and Laura, Marcu and Henry, Hirschberg and Steen, J. Madsen and Andreas, Mandelis and Anita, Mahadevan-Jansen and Jansen, E. Duco, Eds. SPIE, 2010. pp. 754833.
An optical coherence tomography study for imaging the round window niche and the promontorium tympani, Nikiforos, Kollias and Bernard, Choi and Haishan, Zeng and Reza, S. Malek and Brian, J. Wong and Justus, F. R. Ilgner and Kenton, W. Gregory and Guillermo, J. Tearney and Laura, Marcu and Henry, Hirschberg and Steen, J. Madsen and Andreas, Mandelis and Anita, Mahadevan-Jansen and Jansen, E. Duco, Eds. SPIE, 2010. pp. 754833.
File: | 12.848384 |
Bibtex: | @inproceedings{Just, author = {Just, T. and Lankenau, E. and Huttmann, G. and Pau, H. W.}, title = {An optical coherence tomography study for imaging the round window niche and the promontorium tympani}, editor = {Nikiforos, Kollias and Bernard, Choi and Haishan, Zeng and Reza, S. Malek and Brian, J. Wong and Justus, F. R. Ilgner and Kenton, W. Gregory and Guillermo, J. Tearney and Laura, Marcu and Henry, Hirschberg and Steen, J. Madsen and Andreas, Mandelis and Anita, Mahadevan-Jansen and Jansen, E. Duco}, publisher = {SPIE}, volume = {7548}, pages = {754833}, } |
M.
Mueller,
C.
Schulz-Wackerbarth,
P.
Steven,
E.
Lankenau,
T.
Bonin,
H.
Mueller,
A.
Brueggemann,
S.
Grisanti, and
G.
Huettmann,
Slit-lamp-adapted fourier-domain OCT for anterior and posterior segments: preliminary results and comparison to time-domain OCT, Curr Eye Res , vol. 35(8), pp. 722-32, 2010.
Slit-lamp-adapted fourier-domain OCT for anterior and posterior segments: preliminary results and comparison to time-domain OCT, Curr Eye Res , vol. 35(8), pp. 722-32, 2010.
DOI: | 10.3109/02713683.2010.481069 |
Bibtex: | @article{Müller-2010, author = {Mueller, M. and Schulz-Wackerbarth, C. and Steven, P. and Lankenau, E. and Bonin, T. and Mueller, H. and Brueggemann, A. and Birngruber, R. and Grisanti, S. and Huettmann, G.}, title = {Slit-lamp-adapted fourier-domain OCT for anterior and posterior segments: preliminary results and comparison to time-domain OCT}, journal = {Curr Eye Res}, volume = {35(8)}, DOI = { 10.3109/02713683.2010.481069}, year = { 2010}, pages = {722-32}, note = {Using Smart Source Parsing Aug}, abstract = {PURPOSE: To evaluate the diagnostic potential of a slit-lamp (SL)-adapted Fourier-domain (= spectral radar, SR) optical coherence tomography (OCT)-SL-SR-OCT-instrument as an in vivo imaging device for use in examinations of the anterior and posterior segments. MATERIALS AND METHODS: In a pilot study, 88 eyes from 70 healthy volunteers and patients were examined using a prototype Fourier-domain SL-SR-OCT system. Results were compared to those from the following commercially available systems: the 1310-nm SL-OCT (Heidelberg Engineering, Heidelberg, Germany) for anterior segment and the Stratus OCT (Zeiss Meditec, Jena, Germany) for posterior segment imaging. Our SL-SR-OCT provides 1025 axial scans, 5000 Hz line-scan frequency, scan length of up to 8 mm, axial depth in air of 3.5 mm, and resolution of 9 mum. For posterior visualization, a hand-held 78-diopter ophthalmoscopic lens was used. RESULTS: Our SL-SR-OCT system allowed simultaneous scanning with direct biomicroscopic and SL imaging of anterior and posterior segment structures. Anatomical structures and pathological changes were displayed with high resolution and excellent contrast. Measurements of corneal and retinal thickness were possible. In comparison to images obtained by the SL-OCT, our SL-SR-OCT boasted a higher resolution, thus providing more clinically relevant details of the corneal epithelium, internal structure of filtering blebs, etc. Complete imaging of the chamber angle was limited, however, due to the backscattering properties of the sclera at 830 nm. For posterior segment imaging, excellent delineation of the macula and optic nerve head details, with a distinct portrayal of macular pathology and retinal edema, was possible with SL-SR-OCT. CONCLUSION: SL-SR-OCT enables detailed imaging of physiological and pathological anterior and posterior segment structures. As a multi-purpose device, it offers a wide spectrum of applications, with high-quality OCT-imaging, in a comfortable setting without the need to move the patient.}, } |
M.
Wiesner,
J.
Ihlemann,
H. H.
Muller, and
E.
Lankenau,
Optical coherence tomography for process control of laser micromachining, Rev Sci Instrum , vol. 81, no. 3, pp. 033705, 2010.
Optical coherence tomography for process control of laser micromachining, Rev Sci Instrum , vol. 81, no. 3, pp. 033705, 2010.
Joachim
Probst,
Dierck
Hillmann,
Eva
Lankenau,
Stefan
Oelckers, and
Peter
Koch,
Optical coherence tomography with online visualization of more than seven rendered volumes per second, Journal of Biomedical Optics , vol. 15, no. 2, pp. 026014, 2010.
Optical coherence tomography with online visualization of more than seven rendered volumes per second, Journal of Biomedical Optics , vol. 15, no. 2, pp. 026014, 2010.
T.
Just,
E.
Lankenau,
F.
Prall,
H. W.
Pau, and
K.
Sommer,
Optical coherence tomography allows for the reliable identification of laryngeal epithelial dysplasia and for precise biopsy: a clinicopathological study of 61 patients undergoing microlaryngoscopy, Laryngoscope , vol. 120, no. 10, pp. 1964-70, 2010.
Optical coherence tomography allows for the reliable identification of laryngeal epithelial dysplasia and for precise biopsy: a clinicopathological study of 61 patients undergoing microlaryngoscopy, Laryngoscope , vol. 120, no. 10, pp. 1964-70, 2010.
T.
Just,
E
Lankenau, and
H.W.
Pau,
Intra-operative application of optical coherence tomography with an operating microscope., J Laryngol Otol , vol. 123, pp. 1027-1030, 2009.
Intra-operative application of optical coherence tomography with an operating microscope., J Laryngol Otol , vol. 123, pp. 1027-1030, 2009.
T.
Just,
E
Lankenau, and
H.W.
Pau,
Optical coherence tomography of the oval window niche., J Laryngol Oto , vol. 1, pp. 1-6, 2009.
Optical coherence tomography of the oval window niche., J Laryngol Oto , vol. 1, pp. 1-6, 2009.
E.
Lankenau,
C.
Schulz-Wackerbarth,
M.
Müller, and
P.
Steven,
Optical Coherence Tomography: from Retina Imaging to Intraoperative Use - a Review, Klinische Monatsblatter Fur Augenheilkunde , vol. 226, no. 12, pp. 958-964, 2009.
Optical Coherence Tomography: from Retina Imaging to Intraoperative Use - a Review, Klinische Monatsblatter Fur Augenheilkunde , vol. 226, no. 12, pp. 958-964, 2009.
DOI: | DOI 10.1055/s-0028-1109939 |
File: | WOS:000273527800005 |
Bibtex: | @article{Hüttmann2009, author = {Huttmann, G. and Lankenau, E. and Schulz-Wackerbarth, C. and Muller, M. and Steven, P. and Birngruber, R.}, title = {Optical Coherence Tomography: from Retina Imaging to Intraoperative Use - a Review}, journal = {Klinische Monatsblatter Fur Augenheilkunde}, volume = {226}, number = {12}, pages = {958-964}, note = {542VT Times Cited:6 Cited References Count:48}, abstract = {Background: Optical coherence tomography (OCT) is new diagnostic procedure that has rapidly evolved in the last years. The recently developed spectral domain OCT allows one to increase the imaging speed by a hundred times compared to the first generation time domain OCT and enables three-dimensional imaging as well as real-time imaging of fast moving structures. Volumetric imaging improves the quantitative measurement of morphology and the evaluation of temporal changes. In addition, an exact correlation with images acquired with other imaging modalities is possible. Real-time imaging enables also the use of OCT during examinations with the slit-lamp and during ophthalmological surgery. Methods: A spectral domain OCT was adapted to a slit lamp. 70 patients (91 eyes) were examined at the anterior or posterior segment of the eye. Images of healthy structures and different pathologies were compared to OCT images obtained with Stratus 3, Spectralis, and the SL-OCT. To demonstrate the feasibility of OCT during surgery, spectral domain OCT devices working with 20000 and 210000 A scans per second were coupled by specially developed optics to the camera port of a surgical microscope. The device was tested with phantoms and enucleated pig eyes. Results and Conclusions: A5 kHz spectral domain OCT can image the retina during slit lamp-based indirect ophthalmoscopy with a quality similar to that of the Stratus 3. In addition, relevant structures of the anterior segment were imaged. Here, compared to commercially available devices, the imaged field was smaller and the angle of the anterior chamber was not directly visible due to the 830 nm wavelength, which had to be used for retinal imaging. Through the surgical microscope, a volumetric imaging of epithelium, Bowman's, Descemet's membranes, limbus, iris, lens, conjunctiva and sclera was demonstra-ted with several tens of centimetre working distance. Instruments and incisions in the cornea were visualised with 20 mu m precision. Real-time imaging and visualisation of volumetric OCT data were also demonstrated. In principle, all technical problems of an intraoperative use of OCT have been solved and a clinical trial will start in the near future. OCT has the potential to improve the precision of surgical interventions and may even enable new interventions.}, keywords = {physiological optics cornea anatomy in-vivo ultrahigh-resolution anterior segment time-domain blood-flow eye surgery oct cyclophotocoagulation cornea}, ISSN = {0023-2165}, DOI = {DOI 10.1055/s-0028-1109939}, url = {<Go to ISI>://WOS:000273527800005}, year = {2009}, type = {Journal Article} } |
T.
Just,
E.
Lankenau, and
H. W.
Pau,
Optische Kohärenztomographie in der Mittelohrchirurgie, HNO , vol. 57, no. 5, pp. 421-427, 2009.
Optische Kohärenztomographie in der Mittelohrchirurgie, HNO , vol. 57, no. 5, pp. 421-427, 2009.
H. J.
Böhringer,
E.
Lankenau,
F.
Stellmacher,
E.
Reusche, and
A.
Giese,
Imaging of human brain tumor tissue by near-infrared laser coherence tomography, Acta Neurochir (Wien) , vol. 151, no. 5, pp. 507-17; discussion 517, 2009.
Imaging of human brain tumor tissue by near-infrared laser coherence tomography, Acta Neurochir (Wien) , vol. 151, no. 5, pp. 507-17; discussion 517, 2009.
T.
Just,
E.
Lankenau,
G.
Huettmann, and
H.W.
Pau,
Optical coherence tomography as a guide for cochlear implant surgery, in Progress in Biomedical Optics and Imaging , Nikiforos, K. and Bernard, C. and Haishan, Z., Eds. SPIE 6842, 2008. pp. F1-F6.
Optical coherence tomography as a guide for cochlear implant surgery, in Progress in Biomedical Optics and Imaging , Nikiforos, K. and Bernard, C. and Haishan, Z., Eds. SPIE 6842, 2008. pp. F1-F6.
File: | 12.771446 |
Bibtex: | @inproceedings{Just-2008, author = {Just, T. and Lankenau, E. and Huettmann, G. and Pau, H.W.}, title = {Optical coherence tomography as a guide for cochlear implant surgery}, booktitle = {Progress in Biomedical Optics and Imaging}, editor = {Nikiforos, K. and Bernard, C. and Haishan, Z.}, publisher = {SPIE 6842}, pages = {F1-F6}, url = { https://doi.org/10.1117/12.771446}, year = { 2008} } |
E.
Lankenau,
D.
Klinger,
A.
Malik,
H.H.
Müller,
S.
Oelckers,
H.W.
Pau, and
T.
Just,
Combining Optical Coherence Tomographie (OCT) with an operating microscope, in Medical Engineering , Buzug, T.M. and Holz, D. and Weber, S. and Bongartz, J. and Kohl-Bareise, M. and Hartmann, U., Eds. Springer, Berlin, Heidelberg, New York, 2007, pp. pp 343-348.
Combining Optical Coherence Tomographie (OCT) with an operating microscope, in Medical Engineering , Buzug, T.M. and Holz, D. and Weber, S. and Bongartz, J. and Kohl-Bareise, M. and Hartmann, U., Eds. Springer, Berlin, Heidelberg, New York, 2007, pp. pp 343-348.
M.
Löning,
E.
Lankenau,
H.
Diddens,
M.
Krokowski, and
K.
Diedrich,
Optische Kohärenztomographie in der Gynokologie, Der Gynäkologe , vol. 40, no. 5, 2007.
Optische Kohärenztomographie in der Gynokologie, Der Gynäkologe , vol. 40, no. 5, 2007.
A.
Giese,
H.J.
Böhringer,
J.
Leppert,
S.R.
Kandelhardt,
E.
Lankenau, and
P.
Koch,
Non-invasive intraoperative optical coherence tomography of the resection cavity during surgery of intrinsic brain tumors., Proc SPIE , vol. 6078, pp. 495-502, 2006.
Non-invasive intraoperative optical coherence tomography of the resection cavity during surgery of intrinsic brain tumors., Proc SPIE , vol. 6078, pp. 495-502, 2006.
File: | 12.674436.short |
Bibtex: | @article{Giese2006, author = {Giese, A. and Böhringer, H.J. and Leppert, J. and Kandelhardt, S.R. and Lankenau, E. and Koch, P. and Birngruber, R. and Hüttmann, G.}, title = {Non-invasive intraoperative optical coherence tomography of the resection cavity during surgery of intrinsic brain tumors.}, journal = {Proc SPIE}, volume = {6078}, pages = {495-502}, year = { 2006}, url = {https://www.spiedigitallibrary.org/conference-proceedings-of-spie/6078/60782Z/Non-invasive-intraoperative-optical-coherence-tomography-of-the-resection-cavity/10.1117/12.674436.short}, type = {Proceeding} } |
D.
Daniltchenko,
M.
Sachs,
E.
Lankenau,
F.
König,
M.
Burckhardt,
G.
Kristiansen,
D.
Schnorr,
S.
Al-Shukri, and
S.
Löning,
Ex vivo and in vivo topographics studies of bladder by optical coherence tomography, in Saratov Fall Meeting 2004: Optical Technologies in Biophysics and Medicine VI , Tuchin, V., Eds. Proceedings 2005, 2005. pp. 209-14.
Ex vivo and in vivo topographics studies of bladder by optical coherence tomography, in Saratov Fall Meeting 2004: Optical Technologies in Biophysics and Medicine VI , Tuchin, V., Eds. Proceedings 2005, 2005. pp. 209-14.
File: | 12.634810.short |
Bibtex: | @inproceedings{Daniltchenko, author = {Daniltchenko, D. and Sachs, M. and Lankenau, E. and König, F. and Burckhardt, M. and Hüttmann, G. and Kristiansen, G. and Schnorr, D. and Al-Shukri, S. and Löning, S.}, title = {Ex vivo and in vivo topographics studies of bladder by optical coherence tomography}, booktitle = {Saratov Fall Meeting 2004: Optical Technologies in Biophysics and Medicine VI}, editor = {Tuchin, V.}, publisher = {Proceedings 2005}, volume = {5771}, pages = {209-14}, year = { 2005}, URL = {https://www.spiedigitallibrary.org/conference-proceedings-of-spie/5771/0000/Ex-vivo-and-in-vivo-topographic-studies-of-bladder-by/10.1117/12.634810.short} } |
D.
Daniltchenko,
E.
Lankenau,
F.
König,
B.
Shay,
M.D.
Sachs, and
D.
Schnorr,
In Vivo Optical Coherence Tomography in Endoscopic Diagnosis of Bladder Disease, in Clinical technoligies and systems , Vo-Dinh, Tuan, Eds. Proc Soc Photo-Opt Instrum Eng, SPIE 2004, 2004, pp. 473-478.
In Vivo Optical Coherence Tomography in Endoscopic Diagnosis of Bladder Disease, in Clinical technoligies and systems , Vo-Dinh, Tuan, Eds. Proc Soc Photo-Opt Instrum Eng, SPIE 2004, 2004, pp. 473-478.
E.
Lankenau,
M.
Schumacher,
P.
Koch,
F.
König,
D.
Daniltchenko, and
D.
Schmorr,
Dispersion compensation for proximal scanning rigid OCT endoscopes, in SPIE Proc. , 2004. pp. 172-177.
Dispersion compensation for proximal scanning rigid OCT endoscopes, in SPIE Proc. , 2004. pp. 172-177.
File: | 12.531312.short |
Bibtex: | @inproceedings{Lankenau, author = {Lankenau, E. and Schumacher, M. and Koch, P. and König, F. and Daniltchenko, D. and Schmorr, D. and Hüttmann, G.}, title = {Dispersion compensation for proximal scanning rigid OCT endoscopes}, booktitle = {SPIE Proc.}, volume = {5316}, pages = {172-177}, Year = { 2004}, URL = { https://www.spiedigitallibrary.org/conference-proceedings-of-spie/5316/0000/Dispersion-compensation-for-proximal-scanning-rigid-OCT-endoscopes/10.1117/12.531312.short} } |
M.
Löning,
E.
Lankenau,
C.
Strunck,
M.
Krokowski,
S.
Hillbricht, and
K.
Diedrich,
Optische Kohärenztomographie - ein neues hochauflösendes Schnittbildverfahren als Ergänzung zur Kolposkopie, Geburtsh Frauenheilk , vol. 63, pp. 1158-1161, 2003.
Optische Kohärenztomographie - ein neues hochauflösendes Schnittbildverfahren als Ergänzung zur Kolposkopie, Geburtsh Frauenheilk , vol. 63, pp. 1158-1161, 2003.